Xue Da temperature controller Equipment Co., Ltd.
|
Gold Index: 9629
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
220V Portable Electrical Air Cooled Aquarium Industrial Water Chillers Systems for food
In the modern industrial processes, the accurate temperature control is a key factor for improving the productivity and the product quality, and the competitive edage of manufacturing companies relies on the chiller for reducing temperature, improving product quality and production efficiency, and increasingthe profit. To meet the requirements of customers, we offer a series of new design industrial chillers and supporting equipment for plastic machinery and perfect services aiming to minimize the productions costs.
Air-cooled Chillers could work alone without Cooling Tower, however, it has easy- install characteristics.
Applications:
The industrial chillers are used widely in various industries, e.g. the cast blank and suction molding for the plastic production, to shorten the production cycle and inproving the surface finish and transparency; and stabilizing the metallic ions and making it quickly adhering to the companents in the electroplating process; and also used in the chemical, hardware, food, blanching and dyeing, fishery, sauna, central air conditioning and other industries with the need of refrigerating!
Competitive Advantage:
1. High/low pressure protection for the compressor and overheating protection inside the machine .
2. Low water level alarm and low water temperature alarm .
3. Imported compressor from Europe , US and Japan .
4. Refrigerating system welded with oxygen free method ,to reduce oxides and ensure the smooth surface .
5. Throttle components from Danfoss(Denmark) and Alco(US) .
6. SUS304 stainless steel water tank, to avoid corrosion or water leak.
7. Stainless plate, coil, shell and tube or fin type efficient heat exchanger
8. RS485 communication function, to realize automatic management(optional).
9. Electrical devices supplied from OMRON, FUJI, TE, LG.MOELLER and SCHNEIDER.
10.Control mode: imported micro-computer of PLC(optional).
11. Perfect safety protection, failure display, and not requiring professional personnel for maintenance.
12. Highly efficient evaporator and condenser, to save over 30% energy.
13. 2 compressor heads for over AC-80, for individual or operation
Specifications:
Table 1
Model | Unit | AC-1/2A | AC-01A | AC-02A | |
Cooling Capacity | KW 50HZ | 1.53 | 2.94 | 5.67 | |
Kca/h 50HZ | 1316 | 2528 | 4872 | ||
Total Input | KW | 0.68 | 1.31 | 2.6 | |
Maximum Running current | A | 4.1 | 8 | 15.8 | |
Power Supply | 1N ~ 220V 50HZ | ||||
Refrigerant | Name | R22 | |||
Charge | Kg | 0.6 | 0.8 | 1.8 | |
Control Type | Capillary Tube | ||||
Compressor | Type | Hermetic Rotary | |||
Motor | KW | 0.55 | 0.75 | 1.5 | |
Air Flow |
| M3/h | 800 | 1000 | 2000 |
Chilled Water | Flow | M3/h | 0.26 | 0.51 | 0.97 |
Tank | M3 | 0.022 | 0.028 | 0.038 | |
In/Out Pipe | G1/2'' | G1/2'' | G3/4'' | ||
Water Pump | Motor | KW | 0.375 | 0.375 | 0.375 |
Pressure | Kpa | 180 | 180 | 250 | |
Size | Length | MM | 600 | 600 | 820 |
Width | MM | 400 | 400 | 460 | |
Height | MM | 940 | 940 | 1170 | |
Weight | Kg | 45 | 60 | 120 |
Table 2
Model | Unit | AC-03A | AC-04A | AC-05A | AC-06A | AC-08AD | |
| KW 50HZ | 8.39 | 10.90 | 13.95 | 16.90 | 21.80 | |
Kca/h 50HZ | 7216 | 9374 | 11990 | 14530 | 18748 | ||
Total Input | KW | 3.6 | 4.5 | 5.5 | 6.6 | 8.6 | |
Maximum Running current | A | 8.8 | 10.9 | 13.4 | 16 | 20.9 | |
Power Supply | 3N~380V 50HZ | ||||||
| Name | R22 | |||||
Charge | Kg | 2.7 | 3.5 | 4.6 | 5 | 3.5*2 | |
Control Type | Capillary Tube | ||||||
| Type | Hermetic Scroll or Piston | |||||
Motor | KW | 2.25 | 3 | 3.75 | 4.5 | 3*2 | |
Air Flow | M3/h | 3000 | 4000 | 5000 | 6000 | 8000 | |
| Flow | M3/h | 1.44 | 1.87 | 2.40 | 2.91 | 3.75 |
Tank | M3 | 0.06 | 0.06 | 0.07 | 0.11 | 0.11 | |
In/Out Pipe | G3/4'' | G3/4'' | G1'' | G1'' | G1''-1/2'' | ||
| Motor | KW | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 |
Pressure | KPa | 242 | 242 | 290 | 290 | 290 | |
| Length | MM | 945 | 945 | 1035 | 1200 | 1470 |
Width | MM | 550 | 550 | 610 | 650 | 710 | |
Height | MM | 1370 | 1370 | 1385 | 1480 | 1700 | |
Weight | Kg | 130 | 160 | 170 | 250 | 270 |
Remarks:
1. Normal conditions:Chilled water inlet temperature is 12, outlet temperature is 7. Cooling water inlet temperature is 30, outlet temperature is 35.
2. Temperature condition: Chilled water outlet temperature range is 5~15,Cooling water inlet temperaturerange is 19~33
3. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ±10%, allowable voltage difference in phase: ±2%.
4. Accept orders for special requirements.
We reserve the right to make changes to the above specifications without notification.
Our service:
1.Your inquiry related to our products or prices will be replied in 24hours.
2.We can send “Process Cooling&Heating Selection Table” to you for selecting suitable units.
3.We will offer detailed Technical Solution including configuratuion and design idea for you.
4.OEM&ODM, any your customized units we can help you to design and put into product
Service commitment
provides 15 months guarantee since date of bill of lading, all the products are passed strict test, Warranty period caused by product itself factors in the failure, we can replace or recondition the product withou
Xue Da temperature controller Equipment Co., Ltd. [China (Mainland)]
Business Type:Manufacturer
City: Shenzhen
Province/State: Guangdong
Country/Region: China (Mainland)